 4-line EMC filters
Series/Type:
B84144*
The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product Date of Withdrawal 2009-03-13 2009-03-13 2009-03-13 Deadline Last Orders 2009-06-30 2009-06-30 2009-06-30 Last Shipments 2009-09-30 2009-09-30 2009-09-30
B84144G0250S000 B84144B*S120, B84144B*S121 B84144G0500S000 B84144B*S120, B84144B*S121 B84144G1000S000
Ordering Code B84144G1600S000
Substitute Product
Date of Withdrawal 2009-03-13
Deadline Last Orders 2009-06-30
Last Shipments 2009-09-30
For further information please contact your nearest EPCOS sales office, which will also support you in selecting a suitable substitute. The addresses of our worldwide sales network are presented at www.epcos.com/sales.
4-line filters for converters and power electronics
Power line filters for 3-phase systems Rated voltage 440/250 V AC, 50/60 Hz Rated current 16 to 1600 A Alternative version
Series B84144A*R120
B84144A*R, B84144G*S
and B84144B*S120/S121 offer a low-cost solution. Construction
4-line filter Metal case Threaded bushes at end faces for
RF-tight installation Features Optimized leakage current Easy to install Degree of protection up to 180 A: IP 201) Space-saving design Design complies with EN 133200, UL 1283, CSA C22.2 No.8 UL approval

Applications

General applications for power electronics UPS Wind farms For machine tools, textile and packaging machines
Terminals
Finger-safe terminal blocks for filters up to 180 A Busbars for filters 250 to 1600 A
Marking Marking on component: Manufacturer's logo, ordering code, rated voltage, rated current, climatic category, date code Minimum marking on packaging: Manufacturer's logo, ordering code
1) To IEC 60529
Please read Cautions and warnings and Important notes at the end of this document.
2
01/06
4-line filters for converters and power electronics
Typical circuit diagram
LINE L1
B84144A*R, B84144G*S
LOAD L1'
L2
L2'
L3
L3'
N PE
N' PE
SSB1076-F
Technical data and measuring conditions Rated voltage VR Rated current IR Test voltage Vtest 440/250 V AC, 50/60 Hz Referred to 40 C ambient temperature 1770 V DC, 2 s (line/line) 2700 V DC, 2 s (lines/case), for 16 ... 50 A 2550 V DC, 2 s (lines/case), for 80 ...180 A 2121 V DC, 2 s (lines/case), for 250 ... 1600 A 1.5 * IR for 3 min per hour or 2.5 * IR for 30 s per hour At 400 V AC, 50 Hz 25/100/21 (-25 C/+100 C/21 days damp heat test) UL 1283
Overload capability (thermal) Leakage current Ileak Climatic category (IEC 60068-1) Approvals
Please read Cautions and warnings and Important notes at the end of this document.
3
01/06
4-line filters for converters and power electronics
Characteristics and ordering codes
VR AC V
B84144A*R, B84144G*S
IR A 16 25 36 50 80 120 150 180 250 500 1000 1600
Ileak Terminal cross section mA mm2 4 10 10 10 25 50 50 95 Busbars < 3.5 < 3.5 < 3.5 <6 <6 <6 <6 <6 <6 <6 <6 <6
Rtyp m 10 6 3.5 1.3 0.7 0.5 0.35 0.25 0.095 0.060 0.030 0.020
Approx. weight kg 2.2 3.7 3.7 4.0 9.5 10 10 13 32 53 140 185
Ordering code
Approvals
440/250
B84144A0016R000 B84144A0025R000 B84144A0036R000 B84144A0050R000 B84144A0080R000 B84144A0120R000 B84144A0150R000 B84144A0180R000 B84144G0250S000 B84144G0500S000 B84144G1000S000 B84144G1600S000
x x x x x x x x x - - -
x = approval granted Not for new design. Substitute B84144B*S120/S121.
Please read Cautions and warnings and Important notes at the end of this document.
4
01/06
4-line filters for converters and power electronics
Dimensional drawings B84144A0016R000 (16 A)
20.50.5
B84144A*R, B84144G*S
81 max.
550.4
381
PE M6 x 22.5 163 max. 700.2
12.50.4
10.1
600.4 86 max. 4 x M5 x 6
12.51
N L3' L2' L1' 1000.3
N L3 L2 L1
Marking LINE LOAD 5.50.1 141 max.
Terminal blocks 4 mm 2 Tightening torque 0.6 ... 0.8 Nm
113 max.
SSB2221-Q-E
B84144A0025R000, B84144A0036R000, B84144A0050R000 (25 A, 36 A, 50 A)
310.5
91 max.
301
650.4
461
12.50.4
10.1
PE M6 x 25 216 max. 800.2
1000.4 22.51 126 max. 4 x M6 x 6
N L3
LINE
LOAD
6.60.2 166 max.
Terminal blocks 10 mm 2 Tightening torque 1.5 ... 1.8 Nm
156 max.
1400.3
Marking
N L3' L2' L1'
L2 L1
SSB1078-W-E
Please read Cautions and warnings and Important notes at the end of this document.
5
01/06
301
4-line filters for converters and power electronics
B84144A0080R000 (80 A)
48.50.5
B84144A*R, B84144G*S
141 max.
181
1100.4
1.00.1
831
150.4
PE M10 x 32 300 max. 1150.2 6.60.2
1100.4 141 max. 4 x M6 x 6
L1'
L1
LINE
LOAD
221 max.
Terminal blocks 25 mm 2 Tightening torque 4 ... 4.5 Nm
1550.3
N
N
L3'
L3
93.1
Marking
171 max.
L2'
L2
SSB2222-Y-E
B84144A0120R000, B84144A0150R000 (120 A, 150 A)
540.5
181
141 max. 1100.4 1.00.1 871
150.4
PE M10 x 32 348 max. 1150.2 6.60.2
1100.4 141 max. 4 x M6 x 6
LINE
LOAD
261 max.
Please read Cautions and warnings and Important notes at the end of this document.
Terminal blocks 50 mm 2 Tightening torque 6 ... 8 Nm
171 max.
1550.3
96.8
Marking
N L3' L2' L1'
N L3 L2 L1
SSB2223-7-E
6
01/06
551
551
4-line filters for converters and power electronics
B84144A0180R000 (180 A)
B84144A*R, B84144G*S
141 max.
1051
1200.4
160.5
1.20.1 620.8
740.5
100.4
PE M10 x 35 404 max. 301 max.
1100.4 141 max. 4 x M6 x 6
L1'
L1
LINE
LOAD
N
6.60.2 1650.4
N
L3'
L3
100
Marking
Terminal blocks 95 mm 2 Tightening torque 15 ... 20 Nm
171 max.
L2'
1550.3
L2
SSB1087-V-E
Please read Cautions and warnings and Important notes at the end of this document.
7
01/06
4-line filters for converters and power electronics
B84144G0250S000 (250 A)
4 x M8 x 7 4 x M8 x 7
B84144A*R, B84144G*S
350+3
1900.5 L1
1050.5
L2 L3
89.5 110 171_ 4
4
PE M10 x 30 2001 30 o10.5
PE M10 x 30
o12
L1 L2/ N L3 LINE Marking LOAD
L1'
241
L2'/ N' L3'
230+2
2601
24
120
15 _ 3 = 3703 4606 =
SSB0996-A
Please read Cautions and warnings and Important notes at the end of this document.
8
01/06
285
34
N
48
N
N
4.50.5
4-line filters for converters and power electronics
B84144G0500S000 (500 A)
4 x M8 x 7 4 x M8 x 7
60.5
B84144A*R, B84144G*S
500
2100.5 L1 L2 L3
56.5 101.5 134.5 198 _ 4
N PE M10 x 30 2801 o11 L1 L2/ N L3 LINE Marking LOAD 30 o12
N
6
1500.5
N
26
PE M10 x 30
60 150
L1'
30+3
L2'/ N' L3'
2801
250
15 +1 = 5103 5903 =
SSB0997-I
Please read Cautions and warnings and Important notes at the end of this document.
9
01/06
305
4-line filters for converters and power electronics
B84144G1000S000 (1000 A)
4 x M8 x 7 4 x M8 x 7
110.5
B84144A*R, B84144G*S
650+4
3600.8 L1
2400.8
L2
L3
78 163 211 290 _ 3
N PE M12 x 30 3201 o14 L1 L2/ N LINE L3 Marking LOAD 40 o12
N
8
N
28 38
SSB0998-R
PE M12 x 30
65 262
L1' L2'/ N' L3' 40 20+1 =
50+10 400+3 4401 465
=
6603 8403
Please read Cautions and warnings and Important notes at the end of this document.
10
01/06
4-line filters for converters and power electronics
B84144G1600S000 (1600 A)
4 x M8 x 7 4 x M8 x 7
B84144A*R, B84144G*S
680+4
3600.8 L1 L2 L3
110.5 2400.8
N PE M12 x 30 3401 o14 L1 L2/ N LINE L3 Marking LOAD 40 o12
N
N
8
PE M12 x 30
262
L1' L2'/ N' L3' 40 20 +1 =
SSB0999-Z
=
6903 8703
Please read Cautions and warnings and Important notes at the end of this document.
11
50+10 400+3 4401 465
01/06
38
65
28
78 163 211 290 _ 3
4-line filters for converters and power electronics
Insertion loss (typical values at Z = 50 )
B84144A*R, B84144G*S
unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) Filters for 16 ... 36 A
100 dB 80
SSB1677-Q
Filters for 50 A
100 dB 80
SSB1678-Y
B84144A0016 ... A0036R000
B84144A0050R000
60
60
40
40
20
20
0 10 4
10 5
10 6
10 7
Hz 10 8 f
0 10 4
10 5
10 6
10 7
Hz 10 8 f
Filters for 80 A
100 dB 80 70 60 50 40 30 20 10 0 10 4 10 5 10 6 10 7 Hz 10 8 f
SSB1090-F
Filters for 120 and 150 A
100 dB 80 70 60 50 40 30 20 10 0 10 4 10 5 10 6 10 7 Hz 10 8 f
SSB1091-N
B84144A0080R000
B84144A0120R000 B84144A0150R000
Please read Cautions and warnings and Important notes at the end of this document.
12
01/06
4-line filters for converters and power electronics
Insertion loss (typical values at Z = 50 )
B84144A*R, B84144G*S
unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) Filters for 180 A
100 dB 80 70 60 50 40 30 20 10 0 10 4 10 5 10 6 10 7 Hz 10 8 f
04 10 20 40 60
SSB1092-W
Filters for 250 to 1600 A
100 dB
SSB1000-K
B84144A0180R000
B84144G*S000
80
10 5
10 6
10 7
Hz 10 8 f
Please read Cautions and warnings and Important notes at the end of this document.
13
01/06
EMC filters Cautions and warnings
Important information Please read all safety and warning notes carefully before installing the EMC filter and putting it into operation (see ). The same applies to the warning signs on the filter. Please ensure that the signs are not removed nor their legibility impaired by external influences. Death, serious bodily injury and substantial material damage to equipment may occur if the appropriate safety measures are not carried out or the warnings in the text are not observed. Using according to the terms The EMC filters may be used only for their intended application within the specified values in lowvoltage networks in compliance with the instructions given in the data sheets and the data book. The conditions at the place of application must comply with all specifications for the filter used. Warnings
It shall be ensured that only qualified persons (electricity specialists) are engaged on work such

as planning, assembly, installation, operation, repair and maintenance. They must be provided with the corresponding documentation. Danger of electric shock. EMC filters contain components that store an electric charge. Dangerous voltages can continue to exist at the filter terminals for longer than five minutes even after the power has been switched off. The protective earth connections shall be the first to be made when t e EMC filter is installed and h the last to be disconnected. Depending on the magnitude of the leakage currents, the particular specifications for making the protective-earth connection must be observed. Impermissible overloading of the EMC filter, such as impermissible voltages at higher frequencies that may cause resonances etc. can lead to destruction of the filter housing. EMC filters must be prot ected in the application against impermissible excee ding of the rated currents by suitable overcurrent protective.
14
01/06
EMC filters Important notes
The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas o f a pplication. T hese statements are bas ed on o ur know ledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expres sly point out that su ch st atements can not b e reg arded as b inding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than t he customers t hemselves. For t hese reasons , it is always ult imately incum bent on t he customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out in the current sta te o f the art, even if th ey are o perated as specified. I n customer appli cations requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of t he c ustomer a pplication or ot her ac tion t aken by t he cu stomer (e. g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order t o sat isfy c ertain technical requirem ents, some of t he products describ ed in t his publication may co ntain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as "hazardous"). Useful information on this will be found in our Material Data Sheets on the I nternet (www. epcos.com/material). S hould you hav e any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may ch ange from time to time. The same is t rue of the corresponding product specifications. Pleas e chec k t herefore to what ext ent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We a lso reserve the ri ght t o discontinue p roduction a nd d elivery of p roducts. Consequently, we cannot guarantee that all pr oducts named in this publication will always be available. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association (ZVEI). 7. The t rade nam es EPCOS, EPCOS-Jones, Baoke, C eraDiode, CSSP, ML SC, Phas eCap, PhaseMod, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks.
15
01/06


▲Up To Search▲   

 
Price & Availability of B84144G0500S000

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X